Preparation and Corrosion Resistance of Amorphous Micro-Arc Oxidation Ceramic Coating on Pure Magnesium for Biomedical ApplicationsReport as inadecuate




Preparation and Corrosion Resistance of Amorphous Micro-Arc Oxidation Ceramic Coating on Pure Magnesium for Biomedical Applications - Download this document for free, or read online. Document in PDF available to download.

Protective micro-arc oxidation MAO coating was prepared on pure magnesium in aqueous solution without toxic components under a constant current density. The thickness of the coating is over 30 μm after anodizing for 10 min. XRD result shows that the coating is amorphous. The corrosion resistance of pure magnesium with and without MAO coating was evaluated by polarization curve tests in SBF. The results show that the corrosion current density Icorr of the sample with MAO coating is two orders of magnitude lower than that of the sample without MAO coating. Based on the results, it can be concluded that the MAO coating can efficiently divide the substrate from corrosive medium and then the corrosion resistance of the substrate metal is improved significantly.

KEYWORDS

biomedical applications; amorphous structure; micro-arc oxidation; corrosion resistance

Cite this paper







Author: Li-chen Zhao, Chun-xiang Cui, Qian Wang, Yun-liang Geng