MR Assessment of Bile Duct Size in Healthy Individuals: Comparison with US MeasurementsReportar como inadecuado




MR Assessment of Bile Duct Size in Healthy Individuals: Comparison with US Measurements - Descarga este documento en PDF. Documentación en PDF para descargar gratis. Disponible también para leer online.

Collegium antropologicum, Vol.31 No.2 April 2007. -

The purpose of the study was to determine the difference in extrahepatic bile duct EBD size measured by magnetic

resonance MR compared with those measured by ultrasound US. Changes of EBD size related to aging were analyzed

too. Size of EBD was measured in 76 randomly selected healthy individuals. Three radiologists blinded to the result of

other study preformed measurements by US and three different T2 weighted MR sequences. Correlation and linear regression

analysis of obtained data were performed. The mean diameter of EBD measured by US was 3.17mmand by MR

was 3.14 mm on thick slab rapid acquisition with relaxation enhancement TSE, 3.26 mm on thin section single-shot

TSE HASTE and 3.30 mm on coronal fully rewound gradient echo True FISP. There was no statistical difference between

US and different MR sequences p



Autor: Gordana Lovrenčić Prpić - Nenad Babić - Domagoj Marjan - Marija Pećina - Miljenko Marotti -

Fuente: http://hrcak.srce.hr/