Vol 8: Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions.Reportar como inadecuado



 Vol 8: Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions.


Vol 8: Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions. - Descarga este documento en PDF. Documentación en PDF para descargar gratis. Disponible también para leer online.

Descargar gratis o leer online en formato PDF el libro: Vol 8: Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions.
This article is from The Open Biomedical Engineering Journal, volume 8.AbstractThis study is aimed at investigating the variability in resistivity changes in the lung region as a function of air volume, electrode plane and body position. Six normal subjects 33.8 ± 4.7 years, range from 26 to 37 years were studied using the Sheffield Electrical Impedance Tomography EIT portable system. Three transverse planes at the level of second intercostal space, the level of the xiphisternal joint, and midway between upper and lower locations were chosen for measurements. For each plane, sixteen electrodes were uniformly positioned around the thorax. Data were collected with the breath held at end expiration and after inspiring 0.5, 1.0, or 1.5 liters of air from end expiration, with the subject in both the supine and sitting position. The average resistivity change in five regions, two 8x8 pixel local regions in the right lung, entire right, entire left and total lung regions, were calculated. The results show the resistivity change averaged over electrode positions and subject positions was 7-9% per liter of air, with a slightly larger resistivity change of 10 % per liter air in the lower electrode plane. There was no significant difference p0.05 between supine and sitting. The two 8x8 regions show a larger inter individual variability coefficient of variation, CV, is from 30% to 382% compared to the entire left, entire right and total lung CV is from 11% to 51%. The results for the global regions are more consistent. The large inter individual variability appears to be a problem for clinical applications of EIT, such as regional ventilation. The variability may be mitigated by choosing appropriate electrode plane, body position and region of interest for the analysis.



Autor: Zhang, Jie; Patterson, Robert

Fuente: https://archive.org/







Documentos relacionados