Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head modelsReportar como inadecuado




Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models - Descarga este documento en PDF. Documentación en PDF para descargar gratis. Disponible también para leer online.

BioMedical Engineering OnLine

, 3:34

First Online: 13 October 2004Received: 21 May 2004Accepted: 13 October 2004

Abstract

We reviewed articles using computational RF dosimetry to compare the Specific Anthropomorphic Mannequin SAM to anatomically correct models of the human head. Published conclusions based on such comparisons have varied widely. We looked for reasons that might cause apparently similar comparisons to produce dissimilar results. We also looked at the information needed to adequately compare the results of computational RF dosimetry studies. We concluded studies were not comparable because of differences in definitions, models, and methodology. Therefore we propose a protocol, developed by an IEEE standards group, as an initial step in alleviating this problem. The protocol calls for a benchmark validation study comparing the SAM phantom to two anatomically correct models of the human head. It also establishes common definitions and reporting requirements that will increase the comparability of all computational RF dosimetry studies of the human head.

Electronic supplementary materialThe online version of this article doi:10.1186-1475-925X-3-34 contains supplementary material, which is available to authorized users.

Download fulltext PDF



Autor: Brian B Beard - Wolfgang Kainz

Fuente: https://link.springer.com/







Documentos relacionados