1 L2EP - Laboratoire d’Électrotechnique et d’Électronique de Puissance - EA 2697 2 TAS - THALES ALENIA SPACE - Thales Alenia Space

Abstract : This paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in series for reducing the number of transistors and offering a capability of energy management between the sources. Inverter short-circuit fault is considered. Based on the peak-currents obtained in simulation in degraded mode without reconfiguration and with two different reconfiguration strategies, the two proposed topologies can be compared in economic and technical aspects.

Keywords : multiphase machines series connected fault-tolerance open-winding dual-drives short-circuit fault dual-motor aerospace





Autor: Tiago Jose Dos Santos Moraes - Ngac-Ky Nguyen - Fabien Meinguet - Eric Semail -