Subgaleal coiling of the proximal and distal components of a ventriculoperitoneal shuntReportar como inadecuado




Subgaleal coiling of the proximal and distal components of a ventriculoperitoneal shunt - Descarga este documento en PDF. Documentación en PDF para descargar gratis. Disponible también para leer online.

International Journal of Emergency Medicine

, 5:15

First Online: 16 March 2012Received: 15 November 2010Accepted: 16 March 2012

Abstract

Migration is a rare complication of venticuloperitoneal shunts and is thought to be associated with the -memory- of the plastic tubing and the windlass effect of neck flexion and extension. The purpose of this case report is to detail a very rare case of complete distal to proximal shunt migration.

Electronic supplementary materialThe online version of this article doi:10.1186-1865-1380-5-15 contains supplementary material, which is available to authorized users.

Download fulltext PDF



Autor: Brian T Kloss - David M Hart - LaLainia Secreti

Fuente: https://link.springer.com/article/10.1186/1865-1380-5-15