Use of screw locking elements improves radiological and biomechanical results of femoral osteotomiesReportar como inadecuado




Use of screw locking elements improves radiological and biomechanical results of femoral osteotomies - Descarga este documento en PDF. Documentación en PDF para descargar gratis. Disponible también para leer online.

BMC Musculoskeletal Disorders

, 15:387

Orthopedics and biomechanics

Abstract

BackgroundDynamic compression plate DCP constructs provide inadequate fixation in cases of poor bone quality and early weight-bearing. Screw locking elements SLE are flat locking nuts placed at the end of the screw to prevent screw stripping from the bone, improving fixation stability. The purpose of this work was to compare biomechanical and radiological evaluations of femoral ovine osteotomies fixed using DCP constructs with and without SLE.

MethodA dyaphyseal femoral osteotomy was performed in sixteen adult sheep and fixed with a DCP and cortical screws. Half of the animals were operated on with a SLE on each side of the osteotomy and the rest without the addition of SLE. Four animals of each group were euthanized after 8 weeks, and the remaining after 16 weeks. Both femora of each animal were radiographed and mechanically tested in torsion.

ResultsRadiologically femoral malalignment or screw loosening was observed in six out of the eight animals operated on without SLE. In contrast, all animals subjected to the operation with SLE showed complete radiological consolidation of the osteotomy. Seven of these eight animals showed normal femoral alignment and no osteosynthesis failure. Stiffness of the bones fixed with SLE was among 145% and 177% the value of their contralateral non-operated femurs all animals of this group showed greater stiffness on the operated bone than its contralateral non-operated femur. However, stiffness of the bones operated on without SLE was among 58% and 87% the value of the stiffness of their contralateral non-operated bone all animals of this group showed greater stiffness on the non-operated bone than the osteotomized ones.

ConclusionsUse of SLE avoided loosening of the system and stimulated stronger osteotomy consolidation. Clinical application of this improved system may thus be a feasible and cost-effective alternative to other more rigid and expensive bone fixation techniques.

KeywordsOsteotomy Fracture fixation Screw locking elements Dynamic compression plate Electronic supplementary materialThe online version of this article doi:10.1186-1471-2474-15-387 contains supplementary material, which is available to authorized users.

Download fulltext PDF



Autor: Gerardo L Garcés - Oliver Rodríguez - Enrique Rodríguez Grau-Bassas - Syra Roiz - Alejandro Yánez - Alberto Cuadrado

Fuente: https://link.springer.com/



DESCARGAR PDF




Documentos relacionados