Isotropic non-white matter partial volume effects in constrained spherical deconvolutionReportar como inadecuado




Isotropic non-white matter partial volume effects in constrained spherical deconvolution - Descarga este documento en PDF. Documentación en PDF para descargar gratis. Disponible también para leer online.

(2014)FRONTIERS IN NEUROSCIENCE.8(28).p.1-9 Mark abstract Diffusion-weighted (DW) magnetic resonance imaging (MRI) is a non-invasive imaging method, which can be used to investigate neural tracts in the white matter (WM) of the brain. Significant partial volume effects (PVEs) are present in the DVV signal due to relatively large voxel sizes. These PVEs can be caused by both non-WM tissue, such as gray matter (GM) and cerebrospinal fluid (CSF), and by multiple non-parallel WM fiber populations. High angular resolution diffusion imaging (HARDI) methods have been developed to correctly characterize complex WM fiber configurations, but to date, many of the HARDI methods do not account for non-WM PVEs. In this work, we investigated the isotropic PVEs caused by non-WM tissue in WM voxels on fiber orientations extracted with constrained spherical deconvolution (CSD). Experiments were performed on simulated and real DW-MRI data. In particular, simulations were performed to demonstrate the effects of varying the diffusion weightings, signal-to-noise ratios (SNRs), fiber configurations, and tissue fractions. Our results show that the presence of non-WM tissue signal causes a decrease in the precision of the detected fiber orientations and an increase in the detection of false peaks in CSD. We estimated 35-50% of WM voxels to be affected by non-WM PVEs. For HARDI sequences, which typically have a relatively high degree of diffusion weighting, these adverse effects are most pronounced in voxels with GM PVEs. The non-WM PVEs become severe with 50% GM volume for maximum spherical harmonics orders of 8 and below, and already with 25% GM volume for higher orders. In addition, a low diffusion weighting or SNR increases the effects. The non-WM PVEs may cause problems in connectomics, where reliable fiber tracking at the WM G M interface is especially important. We suggest acquiring data with high diffusion-weighting 2500-3000 s/mm(2), reasonable SNR (similar to 30) and using lower SH orders in GM contaminated regions to minimize the non-WM PVEs in CSD.

Please use this url to cite or link to this publication: http://hdl.handle.net/1854/LU-4327780



Autor: Timo Roine, Ben Jeurissen, Daniele Perrone , Jan Aelterman , Alexander Leemans, Wilfried Philips and Jan Sijbers

Fuente: https://biblio.ugent.be/publication/4327780



DESCARGAR PDF




Documentos relacionados